banner

SYD-261 Manual Pensky-Martens Closed-cup Flash Point Tester

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-30 09:13

  • Browse the number:

    122

Send an inquiries
Company Profile
Qingdao Tlead International Co. Ltd
By certification [File Integrity]
Contact:

tlead(Mr.)  

Telephone:

Area:

Beijing

Address:

2606, 7080 Center, No.17 KunShan Road, Qingdao, Shandong, China (266071)

Website: http://tlead.ruer168.com/
Product details
Model Number: SYD-261 Brand Name: 1 Key Specifications/Special Features: Summary:This instrument is designed and manufactured as per standards GB/T 261-2008Determining flash point Pensky-Martens closed cup method and ASTM D93 standard test methods for flash pointUsed to determine the closed cup flash point of the petroleum products in the temperature range from 40℃ to 360℃
  • Main technical features:
    • This instrument is designed as per GB/T261 and ASTM D93
    • The heating power is continuously and stepless adjustable
    • The power is shown visually by voltmeter
    • The temperature control mode is advanced and reasonable
    • The structure is designed small and exquisite
    • Stainless-steel table board is beautiful and easy to clean
    • Operation is easy
    • Test results are precise
    • It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes
  • Main technical specification and parameters:
    • Power supply: AC (220±10%)V, 50Hz
    • Heating device: heating power is continuously adjustable from 0W to 600W
    • Heating rate: (1-12)℃/min, controllable and adjustable
    • Stirring rate:
      • Procedure A: (90-120)rpm
      • Procedure B: (250 ±10)rpm
    • Standard oil cup:
      • Inner diameter: 50.7mm-50.8mm
      • Depth: 55.7mm-56.0mm
      • Scribed line depth of capacity of testing oil: 33.9mm-34.3mm
      • Capacity of testing oil: about 70mL
    • Igniting device:
      • Igniting source: gas (or other civilian fuels, the same as below)
      • Electric ignition, gas flame diameter: 3.2mm-4.8mm
    • Thermometers: mercury in glass thermometer, corresponds with GB/T261-2008 and ASTM E1
    • Scale 5°C-110°C, division 0.5°C
    • Scale 20°C-150°C, division 1°C
    • Scale 90°C-370°C,division 2°C
    • Ambient temperature: ≤35℃
    • Relative humidity:≤ 85Ra
  • Shipping Information:
    • FOB Port: Qingdao
    Main Export Markets:
    • North America
    • Central/South America
    • Asia
    • Australasia
    • Eastern Europe
    • Mid East/Africa
    • Western Europe